Hi, Need Help?

Politique de retour sous 30 jours. En savoir plus

Cliquez ici pour nous contacter.

6054761 | SICK SENSORS | TR10-SLM01C Safety Switch

₹ 48,669.30

Get Best Price on WhatsApp

Product Description

Sensor principle RFID
Locking principle Power to lock
Number of safe outputs 2
Coding Universally coded
Locking force Fmax 1,690 N (EN ISO 14119)
Locking force FZh 1,300 N (EN ISO 14119)
Retaining force 0 N
Actuation directions 4
Weight + 0.4 kg
Housing material ABS
Locking bolt material Stainless steel 304
Mechanical life 5 x 105 switching cycles

 

Warranty

We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.

Delivery and Shipping

We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.


SPARECRUX is NOT an authorized distributor for SICK SENSORS

Manufacturer Part Number (MPN)

6054761

Original Equipment Manufacturer

SICK SENSORS

PDF Product Datasheet
  • 100% Tested & Verified Products

  • GST Invoice Available

  • Warranty Included

  • Trusted by 5000+ Industrial Buyers

Sensor principle - RFID

Locking principle - Power to lock

Number of safe outputs - 2

Coding - Universally coded

Locking force Fmax - $1,690\text{ N}$ (EN ISO 14119)

Locking force FZh - $1,300\text{ N}$ (EN ISO 14119)

Retaining force - $0\text{ N}$

Actuation directions - 4

Approach speed - $\ge 2\text{ mm/s}$

Protection class - II (IEC 61140)

Contamination rating - 3

Classification according to cULus - Class 2

Usage category - DC-13 (IEC 60947-5-1)

Rated operating current (voltage) - $200\text{ mA}$ ($24\text{ V DC}$)

Rated insulation voltage Ui - $75\text{ V}$

Rated impulse withstand voltage Uimp - $1,000\text{ V}$

Supply voltage VS - $24\text{ V DC}$ (20.4 V DC ... 26.4 V DC)

Type of output - Self-monitoring semiconductor outputs (OSSDs)

Output current - $\le 200\text{ mA}$

Safety integrity level - SIL 3 (IEC 61508)

Category - Category 4 (EN ISO 13849)

Performance level - PL e (EN ISO 13849)

PFHD (mean probability of a dangerous failure per hour) - $9.1 \times 10^{-10}$

TM (mission time) - 20 years (EN ISO 13849)

Type - Type 4 (EN ISO 14119)

Actuator coding level - Low coding level (EN ISO 14119)

Safe state in the event of a fault - At least one safety-related semiconductor output (OSSD) is in the OFF state.

EU declaration of conformity - ✔

UK declaration of conformity - ✔

ACMA declaration of conformity - ✔

China RoHS - ✔

cULus certificate - ✔

Third party certificate - ✔

ECLASS 5.1.4 - 27272603

ECLASS 6.0 - 27272603

ECLASS 7.0 - 27272603

ECLASS 8.0 - 27272603

ECLASS 9.0 - 27272603

ECLASS 10.0 - 27272603

ECLASS 11.0 - 27272603