SPARECRUX is NOT an authorized distributor for ALLEN BRADLEY
512-ACA-1-6XXP-24R | ALLEN BRADLEY | NEMA Combination Starter Disconnect
₹ 256,478.70
受取を利用可能か読み込めませんでした
Warranty
We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.
Delivery and Shipping
We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.
Manufacturer Part Number (MPN)
512-ACA-1-6XXP-24R
Original Equipment Manufacturer
ALLEN BRADLEY
説明
Product Code: 512-ACA-1-6XXP-24R
Enclosure Type: NEMA Type 4/4X Stainless Steel
Disconnect Type: Fusible
Fuse Clips: 30A Class R
Overload Relay: Eutectic Alloy
Overload Relay Full Load Amps: Eutectic Overload
Factory Installed Modifications: START-STOP Push Button, Transformer with 2 Primaries & 1 Secondary Fuse, Pilot Lights
Enclosure Size: Size 0
Control Voltage: 120V 60 Hz
Continuous VA (Transformer Rating): 150W
Load Voltage: 220/240V 50/60Hz
Continuous Current Rating: 30A
Service Limit Current Rating: 30A
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase: 3 Hp
Maximum Circuit Closing Inrush Current, Peak Including Offset: 140A
Mechanical Life: 10 million operations
Maximum Number of Auxiliary Contacts: 8
Pick-up Operating Time (Average): 21 ms
Drop-out Operating Time (Average): 16 ms
Wire Size for Power Terminals: 14–10 AWG
Required Torque: 20 lb·in
Type of Power Terminal: Saddle or Wire Clamps
Operating Position: Vertical
Temperature Range: -13°F to +131°F (-25°C to +55°C)
Altitude: 10,000 feet before derating
Corrosion-Resistance: All metal parts are treated for corrosion-resistance
カート
ALLEN BRADLEY
512-ACA-1-6XXP-24R | ALLEN BRADLEY | NEMA Combination Starter Disconnect
₹ 256,478.70
単価 /
利用不可
Product Code: 512-ACA-1-6XXP-24R
Enclosure Type: NEMA Type 4/4X Stainless Steel
Disconnect Type: Fusible
Fuse Clips: 30A Class R
Overload Relay: Eutectic Alloy
Overload Relay Full Load Amps: Eutectic Overload
Factory Installed Modifications: START-STOP Push Button, Transformer with 2 Primaries & 1 Secondary Fuse, Pilot Lights
Enclosure Size: Size 0
Control Voltage: 120V 60 Hz
Continuous VA (Transformer Rating): 150W
Load Voltage: 220/240V 50/60Hz
Continuous Current Rating: 30A
Service Limit Current Rating: 30A
Maximum Hp Rating (Non-plugging and non-jogging duty) Three-Phase: 3 Hp
Maximum Circuit Closing Inrush Current, Peak Including Offset: 140A
Mechanical Life: 10 million operations
Maximum Number of Auxiliary Contacts: 8
Pick-up Operating Time (Average): 21 ms
Drop-out Operating Time (Average): 16 ms
Wire Size for Power Terminals: 14–10 AWG
Required Torque: 20 lb·in
Type of Power Terminal: Saddle or Wire Clamps
Operating Position: Vertical
Temperature Range: -13°F to +131°F (-25°C to +55°C)
Altitude: 10,000 feet before derating
Corrosion-Resistance: All metal parts are treated for corrosion-resistance