30 Days Return Policy. Learn more

Click here to contact us.

SPARECRUX is NOT an authorized distributor for OMRON

E3X-DA11-S | OMRON | Digital Fiber Amplifier Sensor

₹ 5,849.21

Warranty

We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.

Delivery and Shipping

We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.


Enquire Now
Interested in this product? Submit your enquiry by entering your details.

Manufacturer Part Number (MPN)

E3X-DA11-S

Original Equipment Manufacturer

OMRON

説明

Parameter Specification
Power Supply Voltage 12 to 24 VDC ± 10%, ripple (p-p) 10% max.
Power Consumption
  • Normal mode: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
  • Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
  • Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control Output / APC Alarm Output Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 2 V max.
External Input No-voltage input (contact/transistor)
Protection Circuits Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Response Time (Super-high-speed Mode) Operate or reset: 80 μs
Automatic Power Control (APC) Always enabled. High-speed control of emission current. Wide-range APC for the E3X-DA[]R-S
Timer Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer
OMRON

E3X-DA11-S | OMRON | Digital Fiber Amplifier Sensor

₹ 5,849.21
Parameter Specification
Power Supply Voltage 12 to 24 VDC ± 10%, ripple (p-p) 10% max.
Power Consumption
  • Normal mode: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
  • Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
  • Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control Output / APC Alarm Output Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 2 V max.
External Input No-voltage input (contact/transistor)
Protection Circuits Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Response Time (Super-high-speed Mode) Operate or reset: 80 μs
Automatic Power Control (APC) Always enabled. High-speed control of emission current. Wide-range APC for the E3X-DA[]R-S
Timer Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer