Hi, Need Help?

30 Days Return Policy. Learn more

Click here to contact us.

1067049 | SICK SENSORS | MPA-107THTP0B01 Cylinder Sensors

₹ 37,561.50

Get Best Price on WhatsApp

Product Description

Measuring range 107 mm 1)
Housing length 109 mm
Output function Analog, IO-Link
Electrical wiring DC 4-wire
Analog output (voltage) 0 V ... 10 V
Analog output (current) 4 mA ... 20 mA 2)
Supply voltage 15 V DC ... 30 V DC
Power consumption 35 mA, without load
Max. load resistance ≤ 500 Ω Power Output, at 24 V
Min. load resistance ≥ 2 kΩ 1)
Protection class III
Required magnetic field sensitivity, typ. 2 mT ... 15 mT
Resolution, typ.

0.03 % FSR (max. ≥ 0.06 mm) 2)

 3)

Linearity error, typ. 0.5 mm 4)
Repeat accuracy, typ. 0.06 % FSR (≥ 0.1 mm) 5)
Sampling rate, typ. 1.15 ms 6)
Reverse polarity protection Yes

 

Warranty

We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.

Delivery and Shipping

We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.


SPARECRUX is NOT an authorized distributor for SICK SENSORS

Manufacturer Part Number (MPN)

1067049

Original Equipment Manufacturer

SICK SENSORS

PDF Product Datasheet
  • 100% Tested & Verified Products

  • GST Invoice Available

  • Warranty Included

  • Trusted by 5000+ Industrial Buyers

Cylinder type - Universal

Measuring range - 107 mm¹

Housing length - 109 mm

Output function - Analog, IO-Link

Electrical wiring - DC 4-wire

Analog output (voltage) - 0 V ... 10 V

Analog output (current) - 4 mA ... 20 mA²

Supply voltage - 15 V DC ... 30 V DC

Power consumption - 35 mA, without load

Max. load resistance - ≤ 500 Ω (Power Output, at 24 V)

Min. load resistance - ≥ 2 kΩ¹

Protection class - III

Required magnetic field sensitivity, typ. - 2 mT ... 15 mT

Resolution, typ. - 0.03 % FSR (max. ≥ 0.06 mm)²³

Linearity error, typ. - 0.5 mm⁴

Repeat accuracy, typ. - 0.06 % FSR (≥ 0.1 mm)⁵

MTTFD - 240 years

DCavg - 0 %

TM (mission time) - 20 years

EU declaration of conformity - ✔

UK declaration of conformity - ✔

ACMA declaration of conformity - ✔

Moroccan declaration of conformity - ✔

China RoHS - ✔

cULus certificate - ✔

IO-Link certificate - ✔

Information according to Art. 3 of Data Act (Regulation EU 2023/2854) - ✔

ECLASS 5.1.4 - 27270806

ECLASS 6.0 - 27270806

ECLASS 7.0 - 27270806

ECLASS 8.0 - 27270806

ECLASS 9.0 - 27270806

ECLASS 10.0 - 27270806

ECLASS 11.0 - 27270806

ECLASS 12.0 - 27274301